Static Elimination Ball
1.Static Elimination Ball Data Sheet
1. Working power: high performance built-in lithium battery
2. Sleep current: <1mA
3. Working current: <5mA
4. Working temperature: -40 ° C ~ 60 ° C
5. Response time: <1s
6. Grounding resistance: ≤55Ω
7. Explosion-proof grade: ExibIICT6 Gb
8. Static voltage resistance: ±20KV
9. Alarm mode: sound and light alarm (>90dB, 30cm linear distance measurement)
10.Length:1m-1.2m or customized.

2.Application of Static elimination ball
Static elimination ball, also known as electrostatic discharge instrument, is a kind of human body electrostatic discharge product suitable for use in flammable, explosive and anti-static places. The main purpose of developing this product is: in flammable, explosive hazardous areas and anti-static places. Use this product to release the safe electric charge accumulated by the human body itself, to avoid fire and explosion accidents caused by human body static electricity, human body electric shock and reduce the occurrence of electrostatic damage of electronic components.
3.Static elimination ball detection conditions and results
Human body electrostatic voltage 18KV Ambient temperature: 20°C
Five finger release time + 0.091s residual voltage -10V
Five finger release time - 0.090s residual voltage -10V + D4
Palm release time + 0.084s residual voltage -9V
Palm release time - 0.082s residual voltage -9V
Static elimination time meets ESD standards
4.Electrostatic Discharge Ball Pictures



6. Payment Terms

7. Packing & Shipping for wrist strap and heel grounder
One set/carton,Carton size:1m*0.15m*0.15m.
Gross weight:8kgs/carton.
Lead time:1-3 days,Have ready stocks.
Hot Tags: static elimination ball, China, suppliers, wholesale, cheap, price