Anti-static ankle strap test method and precautions
First, testing equipment:
1. Multimeter: Two voltages are required for selection, 10V and 100V respectively; 2. Conductive plate or insulating pad; 3. Steel ball; 4. Aluminum tin; 5. Temperature and humidity box (optional)

Second, the relevant parameters: 1, rubber surface resistance conductive layer 10 ^ 3- 10 ^ 5 Ω. Dissipation layer 10^6-10^9Ω. 2. Conductive ribbon to ground resistance 10^6Ω (1MΩ). The length of the conductive tape is 400-450mm (can be made according to customer requirements). The above parameters are detected by the testing equipment, and the qualified ones are excellent products. If the parameters are unqualified, please do not use them.
Third, anti-static ankle straps in the use of precautions:

1. When using the electrostatic heel strap, each user should wear both feet at the same time to increase the contact time and continuity between the heel strap and the ground, thus reducing the possibility of electrostatic hazard in the human body.
2, conductive ribbon must be in good contact with human skin.
3. It must be used on an anti-static floor or ground where the system is grounded.
4. The anti-static heel strap must be fastened to ensure anti-static effect and safety.
5. Clean regularly and keep clean.