When customers review the processing and manufacturing plants, they often notice the use of anti-static wristbands and conductive shoes worn by employees. These measures will make them have a good impression of the production of the products. A company executive said to one of his key customers: "Whoever has sufficient ESD protection capabilities will have the advantage of a competitive advantage." Another company executive said during the visit to the factory: "The ion fan is impressive, it is a strong commitment to quality, and this will be our choice."
After the customer visits the factory, the factory will be very encouraged, because these measures will ensure that the quality of the product is guaranteed. But they will also try to find employees who don't wear the wristband properly. Of course, this will also make them question the ESD control system and establish a clear control system.
Do not disconnect when using an anti-static wrist strap, otherwise the grounding effect will be lost. The anti-static wrist strap is not tightly buckled, causing the contact resistance between the human skin and the anti-static wrist strap to become large. The resistance of some anti-static wrist straps is the strap itself. When the strap touches the ground, its resistance is greatly reduced, which may result in The danger of electric shock to the human body.
In fact, the anti-static wrist strap is connected to the ground with a special grounding wire with a socket. It cannot be clipped on the metal body of the table or the table, because the resistance of these metal bodies to the ground may be large. Also check the resistance of the antistatic wrist strap frequently.