How to test split clean clothing conductive fiber fabric

Clean room pollution, usually thought of particles, metal ions, chemicals and bacteria. In fact, the biggest pollution in the clean room is dust and static electricity. Especially for industrial clean rooms, air dust and static electricity and protection are very important.
The dust in the clean room can be removed from the equipment by local exhaust, and does not flow into the room; the dust generated in the transportation process of products and materials is generally small and negligible compared with the amount of dust generated by the human body. Therefore, the main amount of dust generated in the clean room is mainly from people, and it can be said that people are the biggest source of pollution in the clean room.
Static electricity has the greatest impact on electronic products, and the circuit is quite sensitive to electrostatic high voltage. When a person or thing with static electricity comes into contact with no device, static release is generated. When the electrostatic high voltage strikes the circuit, the internal oxide film is broken down, damaged, resulting in no device damage or malfunction. Therefore, the key to preventing static electricity from being made in the electronics industry. Dust and static electricity have become an important reason for the quality of electronic products. In order to strengthen the control of dust and static electricity in clean rooms, we must pay attention to the clean performance and electrostatic performance of Class 100 clean clothes.

Class 100 clean clothing
1, 100 class clean clothing (including hats, masks) on the material requirements are:
(1) The amount of dust generated is small, and it is not easy to peel off or break the wire;
(2) It is not easy to generate static electricity and is not easy to adhere to particles;
(3) resistant to organic solvents, washing and steam sterilization;
(4) No mold. Class 100 clean clothing must cover all hair, beards and feet in style, and can prevent the body from falling off to the maximum extent.
2, 100-level clean clothing cleaning standard process:

(1) Sorting: After receiving 100 clean clothes, the customer will sort them first, and then store them in a covered plastic box to prevent the pollution from increasing.
(2) Pre-treatment: For some damages caused by the use of Class 100 clean clothing, such as repair and handling. Pre-decontamination treatment of special-grade cleaned class 100 clean clothes.
(3) Dust-free cleaning: The pre-treated Class 100 dust-free clothing is cleaned by the non-controlled area through the washing machine of the dedicated channel structure and enters the control area (clean room). When the final rinse is permeable, an antistatic agent may be used to improve the antistatic property, but the selected antistatic agent should be well combined with the fiber, and no dust is detached. In order to remove water-soluble contaminants, after washing with water, the final washing is carried out with distilled solvent to remove oily contaminants. The water for wet and dry cleaning is filtered, and the solvent is also distilled, and a filter having a pore diameter of less than 0.2 μm is used at the point of use, and filtration is performed more than once as needed.
(4) Dust-free drying: The cleaned Class 100 clean clothes should be dried in a clean air circulation system dedicated to washing (the dried hot air used is filtered by HEPA).
(5) Folding inspection: After drying, it is folded in a special clean room for washing, and put into a clean polyester bag or nylon bag. It can be double-layered or vacuum-sealed according to requirements. The packaging material is preferably antistatic. Good material. Since the folding process is the most dust-prone, the folding process must be carried out in a high-level purification space. For example, the folding package of the 100-level clean clothes should be carried out in a 10-level environment.
(6) Cleanliness test: The roller (Helmke Drum) tester can test the cleanliness level of dust particles in the cleaned Class 100 clean clothing.
(7) ESD test: ESD performance check to ensure the anti-static performance of Class 100 clean clothing.
(8) Purification and packaging: Passing all the inspected Class 100 clean clothes, sealed and packaged in vacuum packaging bags, it becomes a qualified product, and finally delivered.
Dust-free indoor dust and static electricity are extremely harmful to the product. Class 100 dust-free clothing can minimize the body's dust pollution and prevent static electricity. Therefore, Class 100 clean clothing in clean rooms must undergo rigorous testing to ensure its cleanliness and anti-static properties.