How to reduce static electricity in industrial production

Oct 08, 2020 Leave a message

How to reduce static electricity in industrial production


Anti-static methods commonly used in anti-static workshops

The harm of static electricity is obvious to all. Now more and more manufacturers have begun to implement various levels of anti-static measures and projects. However, we must realize that a perfect and effective anti-static project should be based on the actual situation of different enterprises and different operating objects, and corresponding countermeasures should be formulated. Anti-static measures should be systematic and comprehensive, otherwise, it may get twice the result with half the effort, or even cause destructive reaction. Let's talk about the specific anti-static methods in the workshop.

1. Anti-static work area

1. Floor material: The floor made of electrostatic conductor materials, such as anti-static raised floor or laying anti-static floor mats on ordinary ground, should be used and grounded effectively. It is forbidden to directly use wooden floors or to lay wool, hemp, chemical fiber carpets and ordinary floor leather.

2. Grounding: A. The anti-static system must have an independent and reliable grounding device. The grounding resistance should generally be less than 10Ω. The burying and testing methods should meet the requirements of GBJ 97. B. The anti-static ground wire must not be connected to the power neutral wire or shared with the lightning protection ground wire. C. Use a three-phase five-wire system for power supply, and its earth wire can be used as an anti-static ground wire (but the neutral wire and the ground wire must not be mixed). D. The cross-sectional area of the grounding trunk line should not be less than 100MM2; the cross-sectional area of the branch trunk line should be not less than 6MM2; the grounding wire of the equipment and workbench should be a multi-stranded plastic-coated wire with a cross-sectional area not less than 1.25MM2, and the color of the grounding wire should be yellow-green Appropriate. E. The connection method of the grounding trunk line should be brazed. F. The connecting terminals of the anti-static equipment should ensure reliable contact, easy to assemble and disassemble, and allow the use of various clip-on connectors, such as fish clips and plug sockets. G. Workplaces with higher grounding resistance requirements should install grounding system monitoring and alarm devices, such as the SL-038A grounding system monitoring and alarming device produced by our company, which can monitor whether the ground wire is in good contact with the earth at any time.

3. Ceiling material: antistatic type should be selected, gypsum board products are generally allowed, and ordinary plastic products are prohibited.

4. Wall fabric: Antistatic wallpaper should be used. Generally, plaster paint or lime paint is allowed for walls, and ordinary wallpaper and plastic wallpaper are prohibited.

5. Humidity control: A. The relative humidity of the anti-static work area should not be less than 50%. B. On the premise of not causing harmful effects on the product, it is allowed to use humidifying equipment to spray formulations or water to increase the environmental humidity. C. The humidity of the computer room should meet the relevant regulations in GB 2887, and similar computer rooms should also comply with this regulation.

6. Regional boundaries The anti-static work area should be marked with regional boundaries, and warning signs should be hung in obvious places. The warning signs should comply with GJB1649 regulations. The entrance of the work area should be equipped with ionized air wind bath equipment.

7. Static power source: It is forbidden to use and touch products that easily generate static charges in the anti-static work area. Such as the surface of the workbench painted or dipped paint surface, ordinary plastic veneer, ordinary vinyl and resin surface floor, plastic and ordinary floor leather, polished waxed wood floor. Ordinary vinyl work clothes, caps, shoes, ordinary polyester, synthetic fiber and nylon fabrics, plastic and ordinary rubber-soled shoes operating tools and equipment, ordinary plastic boxes, racks, bottles, tray supplies and paper products, ordinary foam and general moving tools, Compressors, injection equipment, evaporation equipment, etc.

2. Application and management of anti-static products on the production site

1. Ground

Grounding is to connect some anti-static products or other equipment to a ground wire. Use the buried wire method to establish an "independent" ground wire. Make the resistance between the ground wire and the ground less than 10Ω. The function is to discharge the electric charge that may accumulate on the conductor. The static electricity (such as the human body) accumulated on the conductor is usually conducted by grounding.

Grounding is implemented by the following methods:

① The human body is grounded through the wrist strap.

② The human body is grounded through anti-static shoes (or shoe laces) and anti-static floor.

③ The work surface is grounded.

④ Ground the test instrument, tool holder and soldering iron.

⑤ Anti-static floor, ground mat.

⑥ Anti-static transfer vehicles, boxes and racks should be grounded as much as possible.

⑦ The anti-static chair is grounded.

2. Anti-static safety workbench: ①It is composed of workbench, anti-static table mat, wrist strap joint and grounding wire. When necessary, it should also be equipped with static elimination equipment, such as the ion fan produced by our company. ②There should be more than two wrist strap joints on the anti-static table mat, one for operators and one for technicians and inspectors. ③Plastic boxes, rubber, cardboard, glass and other debris that are prone to static electricity are not allowed to be stacked on the anti-static safety workbench. The drawings and materials should be placed in an anti-static document bag.

3. Static electricity elimination equipment: An ion fan should be placed on the product assembly workbench that is prone to static electricity, and the ion fan can be used to blow the product against the product to quickly eliminate the static electricity generated at any time.

4. Anti-static wrist strap: People who directly touch electrostatic sensitive devices must wear an anti-static wrist strap. The wrist strap should be in good contact with the human skin. The resistance of the wrist strap system to the ground should be within the range of 750KΩ-10.5MΩ. The anti-static wrist strap should be checked frequently with a wrist strap tester for damage. The wrist strap tester produced by our company can be used. Companies with conditions or higher requirements are best to use the wrist strap online monitor, because the online monitor is used to connect the wrist strap to the ground wire. Therefore, it can detect whether the anti-static wrist strap is damaged or whether the worker is wearing it at any time.

5. Anti-static clothing: People who enter the anti-static work area and those who touch electrostatic sensitive devices must wear anti-static work clothes, especially in dry environments with a relative humidity of less than 50% (such as winter). Work clothes fabrics should meet the relevant national standards .

6. Anti-static shoes: People who enter the anti-static work area should have anti-static shoes. Persons wearing ordinary shoes should use conductive shoe bundles, anti-static shoe covers or heel straps. Anti-static shoes should be tested frequently with a human body comprehensive tester for their anti-static performance. The SL-033 human body comprehensive tester produced by our company can be used.

7. Anti-static socks: Many companies don't pay much attention to anti-static socks, which is actually wrong. When wearing anti-static shoes, it’s best to wear anti-static socks. If you don’t have anti-static socks, you can also wear cotton wool, but you shouldn’t wear nylon wool because the conductivity of nylon is very poor, which will prevent static electricity from being conducted to anti-static shoes. When I tested a pair of qualified anti-static shoes with a human body comprehensive tester, I found that the resistance was too high because of wearing nylon.

8. Anti-static container: The component holding bags, turnover boxes, PCB loading and unloading racks in the production site should be equipped with electrostatic protection. Metal and ordinary containers are not allowed. If necessary, the container for storing components should be grounded.

9. The conveyor belt and drive shaft used in the production line should be equipped with anti-static grounding brushes and poles. Static elimination equipment can be used on the surface of the conveyor belt, such as the ion fan and ion wind rod produced by our company.

10. The assembly jigs, testing jigs, welding tools, and various instruments used in the production site should be equipped with good grounding wires.

11. Human body comprehensive tester: A human body comprehensive tester should be installed at the entrance of the production site. Everyone who enters the production site should undergo an anti-static test. Only after passing the test can enter the site. Such as the human body comprehensive tester produced by our company. It can detect the integrated resistance of anti-static shoes, wrist straps and the human body.