Ion wind snake operation

Mar 27, 2019 Leave a message

                                                            Ion wind snake operation


1. Connect the air intake pipe to the air inlet of the high frequency ion wind snake.


2. The grounding terminal of the high-frequency ion wind snake is grounded (connected to the machine foot, cold water pipe or special grounding hole, not connected to the hot water pipe or other gas pipe), or the 3-pin plug can be configured without additional grounding. .

3. Turn on the power switch on the high-frequency ion wind snake, the device is in the waiting state, when the light inductor

When the sensor senses the staff, the built-in air valve is opened, the power is turned on, and the device starts to work. At this time, the power indicator and the ion indicator light are on, indicating normal.



4. The high-frequency ion wind snake outputs 5.6KV high voltage, but the current is only 80uA.

There is a weak electric shock when contacting the ion needle. To ensure safety and protect the ion needle,

Please do not touch the ion needle. After prolonged use, wipe the ion needle with alcohol to keep it

clean. The ion needle is damaged or reaches the working life, and the corona discharge cannot be generated normally.

The sub indicator will not light and the ion needle needs to be replaced.

5. It is necessary to remove static electricity from within 3~10cm of the air nozzle, except for the best electrostatic effect, but not

The distance is too close (30mm or more).


6. If the photoelectric sensor is too sensitive, use a plastic screwdriver with a rotating screwdriver to rotate the sensor.

The knob is adjusted clockwise, if not sensitive enough, counterclockwise adjustment.