Ionizer air fan

Jan 04, 2019 Leave a message

To effectively guarantee the service life of the ionizer air fan

FMX-004 field tester

The ion fan series has a small fan to provide wind, and a roller fan to provide wind. The size of the wind can be adjusted by a speed switch over a wide range.


ionizer air fan Features


1. Neutralize static electricity quickly.

2. The ion gas flow covers a large area.

3. The ion mediation range is wide.

4. There is a special ion emitter cleaner.

5. Ionization indicator.

6. The fan has good grounding protection.


The static eliminator consists of a high-voltage power generator and a discharge electrode. The high-voltage corona discharge is used to ionize the air into a large amount of positive and negative ions.

Neutralize the static electricity on the surface of the object.


The wrong use of ionizer air fan shortens its life, so pay attention to the following points when using:

1. The environment should be kept clean and tidy, the surface of the ion fan should be kept clean, and there should be no debris in the inlet and outlet. Regularly remove debris such as dust from the ion fan and the tube.

2. It can only be operated under the condition that the ion fan is completely normal. It is necessary to keep the capacity of the power supply facility sufficient, the voltage is stable, and the phase loss operation is strictly prohibited. The power supply line must be a dedicated line, and the temporary line should not be used for long-term power supply.

 3. During the operation of ionizer air fan, it is found that the fan has abnormal sound, the motor is seriously heated, the outer casing is charged, the switch is tripped, and the switch cannot be started. In order to ensure safety, maintenance is not allowed during fan operation. After the inspection, the test operation should be carried out for about five minutes, and it is confirmed that there is no abnormal phenomenon and then the machine is turned on.

 4. According to the use of environmental conditions, the bearing is replenished or replaced with grease (the motor closed bearing does not need to be replaced during the service life), in order to ensure good lubrication of the ion fan during operation, the number of refueling is not less than 1000 hours. / times, closed bearings and motor bearings, refilling grease filled with 2/3 of the inner and outer rings of the bearing. Oil shortage is strictly prohibited.

 5. ionizer air fan should be stored in a dry environment to avoid moisture in the motor. When the ion fan is stored in the open air, it should be protected from rain. Prevent the fan from colliding during storage and handling to avoid damage to the ion fan.