SL-1000 extended horizontal ion fan
1. Technical parameters
Operating voltage: 220V 50Hz
Current consumption: ≤3.0/1.5Amp
Air volume: 90~ 380CFM(MAX)
Airflow characteristics: 120cm×120cm coverage area
Operating temperature: 32oF(0oC)~122oF(50oC)
Ozone amount: 0.03PPM (measured at 6 inches in front of the smallest fan)
Power: ≤400W
Noise: 55dB minimum
Max 65dB
Outer box: Aluminum plate
Surface; electrostatic spraying
Weight: 15kg (net weight)
Size: 1000mmX220mmX205mm
Ion balance: 0v±10v

2. Time to remove static electricity:
|
Test Conditions |
|||
|
Operating voltage: 110V/220V Test voltage: 1KV~100V Ambient temperature: 22℃ |
|||
|
Tester distance |
Centerline left 300mm |
Centerline |
Centerline right 300mm |
|
300mm |
1.0s |
0.9s |
0.9s |
|
600mm |
1.7s |
1.5s |
1.8s |
*The ion balance voltage and static elimination time meet the ESD standard, and the static elimination time is measured from the test voltage of 1000v~100v.
*The test instrument uses ME268A electrostatic comprehensive tester.
*Test data will vary due to changes in ambient air temperature and humidity.