Standards for common anti-static products

Apr 19, 2019 Leave a message

                                               Standards for common anti-static products


First, the test of the wrist strap

 1. Test standard: ANSI/ESD S1.1

  2, the type of test: Evaluation (laboratory testing);; Acceptanceteating; Functional testing

  3. Test and evaluation indicators: connection line resistance, internal and external resistance of wristband, mechanical strength, system resistance

Second, the test of anti-static clothing

  1. Test standard: ANSI/ESD2.1, IEC61340-5-1-ANNES-A

  2, test and evaluation indicators: sleeve to sleeve resistance, point-to-point resistance, dissipation speed (IEC61340-5-1-ASSEX-A)

  3, test environment: laboratory testing at low humidity 23 ± 3 ° C 12 ± 3% RH ≥ 48H placed and MODERATE HUNIDITY 23 ° C ± 3 ° C, 50 ± 5% RH ≥ 48H placed

  4, indicator requirements: 1 * 10 5 power to 1 * 10 11 power

GM3110 TESTERGM3110 TESTER

Third, the test of the work surface

  1. Test standard: ESD S4.1 resistance measurement, ESDSTM 4.2 charge dissipation characteristic

元素路径: body > p > img
当前已输入1952个字符, 您还可以输入48048个字符。

s

  2, instrument requirements: the same surface resistance measurement requirements

  3, test environment: laboratory testing at low humidity 23 ± 1 ° C 12 ± 3% RH ≥ 48H placed and MODERATE HUNIDITY 23 ° C ± 1 ° C, 50 ± 5% RH ≥ 48H placed

  4. Sample: S4.1: 25.4*61CM, with two grounding points on each sample; S4.2: 61*61CM

  5, the index requirements: grounding resistance 1 * 10 6 power to 1 * 10 9 power, point-to-point resistance ≥ 1 * 10 6 power, power consumption characteristics less than 200V

 6, the test process: laboratorytesting, 70% isopropyl alcohol cleaning, 48 hours of environmental storage after testing. The voltage is selected according to the surface resistance measurement method; Verification of installed works ufraces (Acceptanceteating): 70% isopropyl alcohol cleaning, 15 minutes after drying test; Periodictesting: keep in use, not clean for testing.

  7. Measurement record: highest value, lowest value, average value, ambient temperature and humidity