Static Protection
(1) Human body anti-static system includes anti-static wrist straps, work clothes, caps, gloves, shoes, socks, etc.
(2) Anti-static floor includes anti-static terrazzo floor, anti-static rubber floor, PVC anti-static plastic floor, anti-static carpet, anti-static raised floor, etc.
(3) Anti-static operation series: including anti-static: I: as a table mat, anti-static packaging bag, anti-static logistics trolley, anti-static soldering iron and tools, etc.



Electrostatic measuring instrument.
(1) Electrostatic field tester: It is used to measure the surface resistance values of tabletops and floors. For plane structure and non-plane occasions, different measuring instruments should be selected.
(2) Wrist strap tester: measures whether the wrist strap is effective.
(3) Human body static tester: It is used to measure the amount of static electricity carried by the human body, the impedance between the feet of the human body, the difference in static electricity between the human body, and whether the wristband, grounding plug, work clothes, etc. are effective for protection. It can also be used as an entry discharge to isolate human body static electricity from the workshop.
(4) Megohmmeter: used to measure the impedance or resistance of all conductive, antistatic and electrostatic discharge type surfaces.
Requirements for anti-static technical indicators in the manufacture of electronic products
(1) The ground resistance of the anti-static ground electrode is less than 10Ω.
(2) Ground or floor mat: surface resistance value 105-1010Ω; friction voltage<100V.
(3) Wall: resistance value 5×104-109Ω.
(4) Worktop or pad: surface resistance value 106-109Ω; friction voltage <100V; ground resistance 106-108Ω.
(5) The working chair faces the caster resistance 106-108Ω.
(6) Workwear, hat, gloves friction voltage <300V; sole friction voltage <100V.
(7) The resistance of the wristband connection cable is 1MΩ; the system resistance when wearing the wristband is 1-1OMΩ. The system resistance of the heel strap (shoe bundle) is 0.5×105-108Ω.
(8) The resistance of the logistics platform to the wheel system is 106-109Ω.
(9) The surface resistance of material transfer equipment such as material boxes, turnover boxes, PCB racks, etc. is 103-108Ω; the friction voltage is less than 100V.
(10) The packaging generation, box 1 friction voltage <100V.
(11) Human body comprehensive resistance 106-108Ω.