The Dr Schneider PC SL-004C ion air gun
Use operation and maintenance
The Dr Schneider PC Ion Air Gun is a hand-held, static-dissipating device that provides powerful ion wind to objects. Designed for high air volume dust removal and neutralization of static electricity. Commonly used to eliminate dust attracted by static electricity. The tip of this air gun is not easy to burn out and break. The air gun adopts a wind speed adjustable plastic gun body, which is not only light and the gun body can freely control the size of the wind, and is a kind of static elimination product using the compressed gas series. It has the characteristics of simple installation, stable operation, strong wind speed and fast elimination of static electricity.
Section 1: Principle of action
The Dr Schneider PC SL-004C ion wind gun produces a large number of positively and negatively charged air masses that are blown out at high speed by a compressed gas to neutralize the charge on the object. When the surface of the object is negatively charged, it attracts a positive charge in the gas stream. When the charge on the surface of the object is positive, it attracts the negative charge in the gas stream, so that the static electricity on the surface of the object is neutralized. To achieve the purpose of eliminating static electricity, high-speed compressed gas can also blow away stubborn dust on objects.

Ionization device: The ionization device forms a stable high-strength electric field under the action of low current and high voltage generated by the high-voltage generating device. The ionized air forms an ion body, which is carried out by the high-pressure airflow to reach the surface of the object to neutralize the static electricity and dust removal.
Section 2: Product Features
• Neutralize static electricity quickly.
• The ionized airflow covers a large area.
• Wide range of wind adjustment.
• The air gun has good grounding protection.
Section III: Technical parameters
Operating voltage: 4600V 50Hz
Current consumption: ≤350uA
Air pressure: 40-70PSI
Weight: 0.55kg with line
Operating temperature: 32oF (0oC) ~ 122oF (50oC)
Air flow rate: 10m/sec
Ozone amount: 0.003PPM (6 inches in front of the air gun)
Static elimination time:
* The static elimination time is in compliance with the ESD standard, and the static elimination time is measured from the test voltage of 5000v~500v.
* The test instrument uses the ME269A electrostatic tester.
*The test data will vary depending on the temperature and humidity of the surrounding air.
Section IV: Security
4.1 Read the operating instructions before installation.
4.2 Reliable grounding must be done before operation.
4.3 Inoperable air guns in flammable and explosive environments.
4.4 No repairs may be made without authorization.
Section 5: Installation and operation:
The STICK ST302B ion wind gun is to be used with the ST402A high voltage generator. Insert the end of the air gun cable into the high voltage output jack of the high voltage generator, turn it clockwise to the head, then connect the ground wire of the air gun wire to the grounding bar on the outside of the high voltage generator, and confirm that the grounding is good, then the high voltage generator Plug the plug into the socket with the grounding wire (note the voltage of the high voltage generator), connect the compressed air to the air gun, and turn on the high voltage generator to work.
Note: If you need to choose to install an air filter.
Section 6: Product Warranty and Service

The company strictly abides by: product quality first, credit first, customer first, the following commitments to the product:
1. Warranty period
The warranty period of the products sold by the company is one year. The company will repair the products free of charge due to the quality problems caused by the product's own parts, materials and process problems within one year from the date of sale.
2. After the warranty period
After the warranty period of the products sold by the company, it is still responsible for the labor-free repair of the products to protect the interests of customers. * The static elimination time is in compliance with the ESD standard, and the static elimination time is measured from the test voltage of 5000v~500v.
* The test instrument uses the 7.0KV electrostatic tester.
*The test data will vary depending on the temperature and humidity of the surrounding air.
Section IV: Security
4.1 Read the operating instructions before installation.
4.2 Reliable grounding must be done before operation.
4.3 Inoperable air guns in flammable and explosive environments.
4.4 No repairs may be made without authorization.
Section 5: Installation and operation:

The Dr Schneider PC ion wind gun is to be used with a 7.0KV high voltage generator. Insert the end of the air gun cable into the high voltage output jack of the high voltage generator, turn it clockwise to the head, then connect the ground wire of the air gun wire to the grounding bar on the outside of the high voltage generator, and confirm that the grounding is good, then the high voltage generator Plug the plug into the socket with the grounding wire (note the voltage of the high voltage generator), connect the compressed air to the air gun, and turn on the high voltage generator to work.
Note: If you need to choose to install an air filter.
Section 6: Product Warranty and Service
The company strictly abides by: product quality first, credit first, customer first, the following commitments to the product:
1. Warranty period
The warranty period of the products sold by the company is one year. The company will repair the products free of charge due to the quality problems caused by the product's own parts, materials and process problems within one year from the date of sale.
2. After the warranty period
After the warranty period of the products sold by the company, it is still responsible for the labor-free repair of the products to protect the interests of customers.