The role and risk of ion fan

Mar 11, 2021 Leave a message

The role and risk of ion fan

 Possible ways to ionize the atmosphere: A. Atmospheric corona ionization under strong electric field conditions, generating positive and negative ions; B, A rays and β-rays interact with atmospheric molecules to make them atmosphere ions; C, high-energy rays (X-rays) The atmosphere separation sub-fan makes the radical ionize; the characteristics of the atmosphere ions, the atmosphere ions are different from the solution ions, it must be a certain energy to be born, and usually exists in the form of molecular clusters;, the atmosphere ions also exist in the natural environment, but the concentration is very low ;. In a clean atmosphere, the life of atmospheric ions is between a few seconds to a few minutes;, positive and negative ions will neutralize each other when they meet; several issues that need to be considered in the use of ion static eliminators, and two aspects of the action interval. Elements: A. The closer the interval, the faster the static elimination rate; B. The useful interval difference of the ion static elimination device of different types.

  The function and hazard of ion fan, the principle of ion static elimination device in addition to static electricity: natural atmosphere ions act on the static electricity source to neutralize static electricity.

  The discharge needle of the ion static eliminator of the strong electric field ionization method is the most prone to aging and damage. The regular cleaning and conditioning can ensure the use of the equipment.

  Elimination of static electricity rate: considering the target-the dissipation rate, the CPM is usually used to measure the dissipation rate of 1000V-100V; Ion balance: Ion unyielding will cause objects in the active area to bring surface tortoises, so it must be controlled. Ion unyielding only appears in the ionization equipment of corona ionization; Other considerations: different types of ionization equipment, practical tools, different types of ion fans, exchange ion fans:

  Possible ways to ionize the atmosphere: A. Atmospheric corona ionization under strong electric field conditions, generating positive and negative ions; B, A rays and β-rays interact with atmospheric molecules to make them atmosphere ions; C, high-energy rays (X-rays) Atmospheric ions allow radicals to ionize; the characteristics of atmospheric ions and atmospheric ions are different from solution ions, and they must have certain energy to be born, and usually exist in the form of molecular clusters; atmospheric ions also exist in the natural environment, but the concentration is very low; In a clean atmosphere, the lifespan of atmospheric ions is between a few seconds to a few minutes; positive and negative ions will neutralize each other when they meet; there are several issues that need to be considered in the use of ion static eliminators, and two elements of the action interval: A. The closer the interval, the faster the static elimination rate; B. The useful interval of the ion static elimination device of different types is different.

  The plan is simple and the cost is low; the stable, sine wave ionization compliance is low, and it is not suitable for places where rapid neutralization is necessary; the differential positive ionization energy makes it difficult to balance the ionization; the occurrence period of positive and negative ion surrogacy is 1 /100 or 1/120 seconds (50 or 60HZ) the natural neutralization of ions will further lower the compliance, and high wind compensation is necessary; due to the low compliance, a larger voltage is necessary to generate sufficient ions, which will form a lot of particles, unfortunately Use in harsh dust-free environment.

  Direct current ion fan, continuous high-voltage utilization ionization has high compliance, can deal with and quickly neutralize the necessity;, can use lower voltage, can be used as a dust-free workshop;, can use active measurement and reaction to control ionization balance;, necessary Huge control circuit to ensure the balance of positive and negative ions.

  High-frequency exchange ion fan, high-frequency exchange methods above 3000HZ can greatly improve the exchange ionization compliance; lower ionization voltage can be used; excellent ion balance; discharge needles do not need to be grouped, and the size can be made very large Small, suitable for use in a dust-free workshop, short action interval, wind compensation.

  The pulsed direct current ion fan and the ion group generated by the pulse eliminate the natural and neutral environment. Allow the ionizer to be far away from the shielding tool (up to 5 meters); 、It is most commonly used in dust-free workshops where there are probably low atmosphere activities; 、The pulse time can be adjusted to suit the airflow or interval requirements of the environment; 、Pulse wave Initiating a "voltage swing" voltage change may be unlucky for some devices.