Why use anti-static floor mats in computer rooms

Jun 05, 2020 Leave a message

Why use anti-static floor mats in computer rooms


Anti-static floor mats are also called static conductive floor mats. As people walk, shoes will rub against the floor to generate static electricity. Charged ions will attract dust in the air on the floor surface, which will cause certain damage to computer rooms, electronic workshops and other units. influences. Electrostatically conductive floor mats are floor mats that can conduct static electricity. Under the construction, copper foil should be laid under the ground mat. The copper foil should be connected to the underground buried conductor to let the static electricity generated by the ground directly enter the ground, so that the ground is free of static ions The laying of the mat should be done with conductive glue.

Anti-static floor mats can be made in two forms, one is overhead anti-static floor, and the other is anti-static rubber floor mat. Overhead anti-static floors are generally suitable for rooms that require a lot of wiring, such as computer rooms, computer rooms, host rooms, and monitoring rooms. Anti-static rubber floor mats are generally used in rooms with less wiring, such as electronic workshops and production workshops, where anti-static requirements are required.

In the computer room, in order to prevent the negative impact of static electricity on the equipment in the computer room, you must consider installing and using anti-static raised floors. Because it provides the following advantages:

1. It simplifies installation and provides greater flexibility for future equipment configuration changes and expansions.

2. The equipment in the equipment room can be freely connected through the anti-static floor, which is convenient for laying and maintenance, and makes the equipment room clean and beautiful.

3. It can protect various cables, wires, data lines and sockets from damage.

4. The machine room can use the space under the floor as the static pressure air storage of the air conditioner to obtain a satisfactory air flow organization. No matter where the computer equipment is installed, the air-conditioned air can be obtained through the air outlet of the anti-static raised floor.

5. Conducive to the repair and maintenance of the bottom of the device.

6. Eliminate the harm of exposed cable to human body.

7. The adjustability of the anti-static raised floor can be used to eliminate the unevenness of the real ground and ensure the overall level of the ground in the equipment room.

8. It can make the static charge leak to the ground and reflect electromagnetic radiation.