Anti-static technical requirements for electronic equipment manufacturing
1. Subject content and scope of application This standard stipulates the basic requirements for the protection technology against electrostatic discharge hazards in the whole process of D-electronic equipment development and production; the anti-static operation requirements during the procurement, testing, storage, transportation and assembly of electrostatic sensitive devices, The management of anti-static work area and personnel education and training.
This standard is applicable to the electrostatic protection of electronic equipment development, production, maintenance and procurement, storage and transportation of electronic components.
2 Reference standard
GB 2887-89 computing station site technical conditions
Technical requirements for GB4385-1995 anti-static rubber sole shoes and conductive rubber sole shoes
GB12014-89 anti-static overalls
Industrial enterprise communication grounding design specification
GJB1210 Grounding, Lap and Shield Design Implementation
GJB1649-1993 Electronic product anti-static discharge control program
3 terms
3.1 electrostatic electrostatics
Excessive or insufficient static charge on the surface of the object.
3.2 Electrostatic discharge (ESD)
After the energy of the electrostatic electric field reaches a certain level, it breaks down its profile and discharges.
3.3 Electrostatic sensitivity electrostatic susceptivity
The value of the electrostatic discharge voltage that the component can withstand.
3.4 static sensitivity device (SSD)
A device that is sensitive to electrostatic discharge.
Note: The sensitivity classification of electrostatic sensitive devices is referred to GJB l649-93 Appendix A.
3.5 bleed leakage
Pass the static charge safely to the ground.
3.6 Neutralization and neutralization
The use of a conductive charge causes the static electricity to disappear.
3.7 electrostatic conductor
Approved by the Ministry of Electronics Industry of the People's Republic of China from 1994-08 to 08. 1994-12-01 Implementation SJ /T 10533-94 Objects with surface resistance values in the range of 105 to 1010.
3.8 Grounding ground g
Electrically connected to an object that can provide or accept a large amount of charge (such as earth, ship or vehicle metal casing, etc.).
3.9 anti-static work area
A work site formed by various anti-static facilities, devices, and clear regional boundaries.
4 basic requirements
4.1. Basic principles of electrostatic protection
a. Suppressing the accumulation of static charges;
b. Quickly, safely and effectively eliminate the static charge that has been generated.
4,2 anti-static work area
4.2.1 Ground materials
4.2.1.1 It is forbidden to use wood flooring directly or to lay wool, linen, chemical fiber carpet and ordinary floor leather.
4.2.1.2 The ground made of electrostatic conductor material, such as anti-static raised floor or anti-static mat on ordinary ground, should be selected and effectively grounded.
4.2, 1.3 It is permissible to use specially treated terrazzo floors, such as laying a ground wire, carburizing or spraying antistatic agents on the ground.
4.2.2 Grounding
4.2.2.1 The anti-static system must have an independent and reliable grounding device. The grounding resistance should be less than 10Ω. The embedding and testing methods should meet the requirements of GJB1210.
4.2.2.2 The anti-static ground wire shall not be connected to the power supply neutral line and shall not be shared with the lightning protection ground wire.
4.2.2.3 Using three-phase five-wire system, the ground wire can be used as an anti-static ground wire (but the neutral wire and ground wire must not be mixed).
4.2.2.4 The cross-sectional area of the grounding trunk line shall not be less than 100mm2, and the cross-sectional area of the trunk line shall be not less than 6mm2. The grounding wire of the equipment and the workbench shall be a multi-strand plasticized wire with a cross-sectional area of not less than 1.25mm2. It is better to use yellow-green lines.
4.2.2.5 The connection method of the grounding main line shall be brazed.
4.2.2.6 Anti-static equipment connection terminals should ensure reliable contact, easy to install and disassemble, and allow the use of various clip-type aluminum, such as squid clips, plugs, etc.
4.2.3 Ceiling material
Ceiling materials should be made of antistatic materials. Under normal circumstances, gypsum board products are allowed, and ordinary plastic products are prohibited.
4.2.4 Wall fabric
Anti-static wallpaper should be used for wall fabrics. Gypsum paint or lime paint wall is generally allowed. It is forbidden to use ordinary wallpaper and plastic wallpaper.
4.2.5 Humidity control
4.2.5.1 The relative humidity of the anti-static work area is not less than 50%.
4.2.5.2 Allow the use of humidification equipment to spray the preparation or water to increase the ambient humidity without adversely affecting the product.
4.2.5.3 The humidity of the computer room shall comply with the relevant provisions of GB 2887, and similar computer rooms shall also comply with this regulation.
4.2.6 Regional boundaries
The anti-static work area shall indicate the boundary of the area, and the warning signs shall be hoisted at obvious places. The warning signs shall comply with the provisions of GJB 1649, and the ionized air air bath equipment shall be arranged at the entrance of the work area.
4.2.7 Charge source
It is forbidden to use and contact the charge source which is easy to generate static charge in the anti-static work area.
4.3 Anti-static facilities
4.3.1 Static Safety Workbench
4.3.1.1 Static safety workbench is an essential part of the anti-static work area. It consists of a workbench, an anti-static table mat, a wristband connector and a grounding wire.
4.3.1.2 There shall be no less than two wrist strap connectors on the anti-static table mat, one for the operator and the other for the technician, inspector or other personnel.
4.3.1.3 If necessary, an electrostatic wind static eliminator shall be provided on the electrostatic safety workbench.
4.3.1.4 Electrostatic safety worktables are not allowed to stack plastic boxes (sheets), rubber, cardboard, glass, etc., which are prone to static electricity. Drawings and materials should be placed in anti-static paper bags.
4.3.2 Anti-static wrist strap
Persons who are in direct contact with electrostatic sensitive devices should wear anti-static wristbands. The wristbands should have good contact with human skin. The wristbands must be non-irritating and non-allergic to the human body. The resistance of the wristband system to ground should be 106-108 ohms. Within the scope.
4.3.3 Anti-static container
In the development and production of electronic equipment, all storage and turnover SSD containers (component bags, transfer boxes, printed boards, component storage boxes, etc.) should have electrostatic protection. Metal and ordinary plastic containers are not allowed. If necessary, the tote box for storage parts should be grounded.
4.3.4 Ion wind static eliminator
To eliminate the static charge on the surface of the insulating material, an ion wind static eliminator should be used.
4.3.5 Anti-static overalls
4.3.5.1 Enter the anti-static work area or touch the SSD. Personnel should wear anti-static overalls, anti-static overalls fabrics should meet the requirements of GBl2014.
4.3.5.2 In the environment with relative humidity greater than 50%, anti-static overalls are allowed to use pure cotton products.
4.3.6 Anti-static work shoes
Persons entering the anti-static work area or contacting the SSD should wear anti-static work shoes. The anti-static work shoes should meet the relevant requirements of GB:4385. Normal shoes are generally allowed, but conductive shoe bundles or heel straps should be used at the same time.
4.3.7 Anti-static transport vehicles When transporting SSDs or integral parts containing SSDs, transport vehicles with anti-static properties should be used.