Anti-static wrist strap alarms need to meet those requirements before they can alarm
Anti-static wrist strap alarm function, it is mainly to monitor the current working state of the wrist strap worn by the staff, and continuously monitor the wrist strap. It is mainly affected by the static resistance of the staff's own body resistance and the working environment (anti-static floor, anti-static shoes, work clothes, table mats, chairs, etc.), and the fine-tuning is adjusted to make it work normally.

The minimum measurement resistance of the anti-static wrist strap alarm is 800K ± 10% ohm. The detection method is as follows: adjust the fine adjustment of the online monitor to the rightmost end, connect the ground wire and the power supply, the red light flashes, and accompanied by an alarm sound, connect one end of the adjustable resistance tester to the ground wire, and the other end and the wrist. With the jack connection, then slowly slide the adjuster so that its red light turns green and the alarm sound disappears. The resulting resistance is the minimum range of the online monitor.

The maximum measurement resistance of the anti-static wrist strap alarm is 2M. Do not insert the wrist strap, directly connect the ground wire, adjust the fine adjustment to the left, you can not consider the green light when the air is displayed, because the body's own body resistance impedance is about 1M, the impedance of the wrist strap is 1M ± 5%, other static electricity The impedance brought by the measure will not be greater than 1M.

In the normal working situation, the staff wears a wrist strap to adjust the fine adjustment, and adjusts the fine adjustment when the red light turns into the green light's critical point, and the adjustment is completed.
If there is a problem with this instrument, the fine adjustment will be out of control when the fine adjustment is adjusted, and it will not work normally.