How should the clean clothes be tested?
After the dust-free cleaning, the work clothes will be directly used in various dust-free workshops. In the workshop where high-precision products are produced, any abnormality in one link may damage the quality of the final product. If the dust particles on the work clothes exceed a certain control range, they will fall into the dust-free environment because the wearer walks back and forth. These particles will have the opportunity to fall on the final product. Clean clothes are an important part of the dust-free environment. It is very important to monitor it.


▲ESD test
ESD performance is an important indicator for evaluating the quality of work clothes. The general ESD test has four parts: friction voltage test, static voltage test, resistance test, and decay time test.
Friction voltage test

This test is mainly to verify whether the fabric itself can reach a specified stable value in a short time after accumulating some voltage after friction. This is mainly to check the quality of the conductive wire.
* Test method, on a dedicated ESD test bench (grounded), the tester rubs the surface of the fabric several times (usually 5-10 times) with a certain amount of force and speed, and then separates the probe with a dedicated voltage tester. Align the rubbed portion around 5 cm and read the voltage value after the 5th second.
* Test standards, the requirements for clothing ESD in the semiconductor industry are generally less than 100V. Some industries have more stringent standards, such as wafer and head industries, and the friction voltage is generally less than 20V.

Static voltage test
This test is to verify how much the fabric itself can stay through the conductive wire after accumulating a certain amount of static electricity in the environment.
* Test method, put the tested clothes on a special test bench, and use the ESD tester's probe to read the voltage value about 5CM apart.
Test standards, depending on the design criteria of the customer's work clothes, the most stringent can be required to be less than 5V. Generally, it is more common at around 50V.
Surface resistance test
This test verifies the electrical conductivity of the conductive filament and the requirements of the stitching process before the fabric and the fabric, such as the connection between the conductive filaments.

*Test method, put the tested work clothes on a special test bench, test it with a resistance tester, usually need to test different points of the work clothes, like a piece of cloth, between different cloth blocks, sleeves and Between the sleeves, between the pants and the pants.
* Test standards, according to the standards of the semiconductor industry, most companies control the resistance of the work clothes at 105-109 ohms, and also strictly set at 105-107.
▲ Decay time
The test is mainly to verify how long the conductive filament of the fabric can dissipate the high pressure to a certain extent after the high pressure is applied.
Most fabrics have a decay time of less than 0.5 seconds, depending on the customer.