Static eliminator installation requirements
1. General regulations
1) The field power wiring should be correct, safe and reliable, and the grounding line of the electrical equipment should be well grounded (the connection resistance to the common grounding point is less than 1 ohm).
2) The on-site compressed air circuit should be clean and dry, free of dust, grease and moisture.

2, mandatory regulations

The explosion-proof static eliminator has special conditions for its safe use. In the process of construction, installation and use, the product explosion-proof certificate, product use instructions and relevant national standards for explosive electrical environment equipment should be strictly observed.

3. Principles for installation
1) The static eliminator should be installed in an area with antistatic requirements.
2) When installing the static eliminator, the technical requirements for product use should be followed, and the electrical grounding of the equipment is good.
3) Ensure that the static eliminator discharge electrode maintains a certain safe distance from the surrounding metal parts, and can follow the requirements in the product's instructions for use.
4) There should be no cover on the surface of the static eliminator.
5) The installation interval of the static eliminators should be based on the requirements of the site anti-static area setting requirements and product use instructions, comprehensive consideration, determine the optimal installation interval, or consult the product supplier.
6) The air inlet of the ion fan type static eliminator should maintain the necessary distance from the surrounding obstacles. For details, please refer to the product instructions, or consult the product supplier.
7) There should be no obstacles between the installation position of the static eliminator and the object to be neutralized.

4. After the installation of the static eliminator is completed: the static eliminator should be in the standby or closed state, and then restarted after commissioning, trial operation and formal use.