What to do if the static grounding alarm keeps on
The electrostatic grounding alarm is a device to eliminate the static electricity of the human body. This is the electrostatic grounding alarm to indicate whether the human body is discharged with static electricity. If the electrostatic grounding alarm does not sound or keeps ringing, it may be an electrostatic grounding alarm There is a problem, the editor of the honeypot decoration network will introduce to you the corresponding treatment methods for the static grounding alarm to keep ringing and not ringing for your reference.



The static grounding alarm does not sound? What if I don't call the police?
When the electrostatic grounding alarm does not alarm when the electrostatic grounding clamp is opened, it may be caused by a short circuit in the detection circuit, sleep of the alarm module, failure of the alarm module, etc. Please check as follows:
1. Remove the 4 terminals of the electrostatic grounding clamp and the wire. If the alarm is restored, it means that there is a short circuit in the detection circuit. Please check the circuit, otherwise enter the second and third steps
2. Short-circuit terminals 1, 4 with a wire for 3 seconds, and then disconnect it. If the alarm resumes, it means that the alarm module has automatically entered the dormant state due to the continuous alarm for more than 8 minutes, and has been awakened and entered normal operation, otherwise it will enter the third step
3. Check whether the insulation gasket of the center and the clamp body is detached causing the detection circuit to be short-circuited. If so, please replace the insulation gasket, otherwise please check whether the cable is short-circuited or the alarm module is faulty