Anti-static mat use principle
First, the requirements of the foundation ground The requirements of the foundation bottom surface can be the bottom surface of the water mill and the bottom surface of the porcelain.
The ground should be flat, no obvious unevenness, and the unevenness should be less than two thousandths.
The ground has sufficient strength and no sanding or shelling.


The ground is dry.
Second, the green surface is for storing and absorbing the static electricity around the tabletop. Its resistance 10 is 7th to 10th to the 9th power Ω, and the black bottom is ≤10 to the 6th power Ω/cm, which can be absorbed quickly by the conductor. Static electricity discharge, one end of the grounding wire is connected to the anti-static mat, and the other end is connected to the ground. Therefore, the static electricity is smoothly discharged to the earth through the grounding wire, so that the static electricity around the desktop is discharged through this principle.
Use the anti-static floor mat. Place an anti-static mat on the table, and then fasten the end of the anti-static grounding wire to the surface, and connect the other end to the grounding conductor. This will pass the static electricity collected on the desktop to the anti-static grounding. The line is vented.
Third, the construction procedures and specific methods with 120 # gasoline or toluene to clean the ground magazine (using the cleaning machine floor laying copper or aluminum strip, such as copper strip thickness of 0.02mm, width of 30mm, the number of strips according to the actual requirements of the ground laying To measure the length and quantity while guiding the other end of the laying strip to the ground.
After the grounding guide is laid, clean and dry the floor, apply conductive glue, dry for 20-30 minutes, until the hand is not sticky, the bottom of the anti-static mat (black surface) is the same (coating conductive glue once), then put The anti-static rubber sheet is bonded to the ground, and then rolled with heavy weight for 5 times to make the surface of the anti-static rubber smooth and flat, and it can be used after 48 hours at normal temperature.
The ambient temperature requirement during construction shall not be less than 25 °C and the temperature shall not be greater than that of ventilation.
The conductive adhesive has a resistivity of not more than 108 Ω and a peeling strength of KG/2.5 cm.
It can be coated with conductive glue, or it can be pasted on the surface of copper strip.