Anti-static table mat needs to be grounded


When the anti-static table mat is grounded, it should be connected to the anti-static ground wire. Some companies do not have real anti-static grounding for cost considerations. They use the equipment grounding wire, or even connect it to the water pipe, or connect it to some Go to a ground wire of a three-phase circuit. It is recommended that you connect it to a dedicated anti-static ground wire. The real anti-static ground wire, why do you say that? Because different ground wires have different functions, it is better to connect anti-static ground wires if you consider anti-static. Because equipment ground wires, lightning protection ground wires, and lighting ground wires, they all have If your own balance point is different from our actual balance point, it will cause voltage drift or zero point drift. In fact, there is no real grounding. Therefore, the anti-static pad must be connected to the anti-static grounding wire. Go up, so as to ensure that the quality of anti-static products will not cause problems, and the static electricity can be discharged well.
Some standard methods for grounding of anti-static table mats are for everyone to introduce, the specific methods:
A. Lay the anti-static table mat on the workbench, and install the anti-static ground wire on the corner of the workbench;
B. Cut a small opening on the anti-static table mat and insert it with the star claw part of the ground wire. The star claw must be fastened to the anti-static table mat;
C. The other end of the anti-static grounding wire is an anti-static grounding bus with alligator clips;
D. Measure whether the anti-static grounding wire, anti-static table mat and the ground are connected, and the test is passed, that is, the anti-static grounding device is basically completed.