Precautions for using Ion Wind Snake



The high-pressure ion wind snake is a high-precision and flexible static electricity elimination product. When meeting its application standards. When all high-voltage static elimination equipment is used at work, it is necessary to frequently check whether the products have achieved static elimination and whether there are any abnormalities. If any abnormalities are found in some of the products, evacuate the work area immediately and contact the supplier. Dealer processing.
The connection between the nozzle of the air gun and the high-voltage wire does not need to be bent and turned frequently, because the connection between the nozzle and the gun handle is made of metal and the high-voltage wire is easy to break, which can easily lead to ignition charge and discharge damage. The Wind Snake is a high-voltage electronic device that must ensure that the power is cut off when people are away from it.
When adjusting the position of the vent, you should operate it with both hands at the same time. Do not use one hand to bend the sheet metal. This can prevent the high-voltage electrode wire position from being damaged.
Before use, open the pneumatic valve first, and then turn on the power supply. This operation can effectively avoid the possibility of the top of the ion wind snake electrode needle being burned due to short circuit failure. Because of environmental factors such as indoors and outdoors in winter and summer.
After the compressor stops working, the wall thickness of the bronchus is reduced and solidifies into water droplets. If we start working and turn on the pneumatic valve and power supply at the same time, the result is that the thick water droplets accumulate into water droplets and pass through the entrance of the first ion wind snake. At this time, the ion wind snake will be burned due to short circuit failure.
The correct operation method is: first open the pneumatic valve and air blow until there is no obvious water vapor in the blown pneumatic valve, and then turn on the power supply to start work. When not working, first cut off the power and then close the pneumatic valve.
When using the ion wind snake with a sensor for the first time, the reasonable distance between the sensors must be adjusted on the spot according to the actual operation. Generally, the distance will be around 20 cm. If you don't know the actual operation, you can consult the supplier or manufacturer.
All products used without grounding power supply, unclean pneumatic valves, or unauthorized disassembly and modification of the structure, as well as failure, damage and other adverse effects caused by careless use are not covered by our warranty and liability.