Dr.Schneider pc SL-031 human body comprehensive tester! Instruction manual

The Dr. Schneider pc SL-031 double-body integrated tester is designed to measure the overall resistance of the human body, including the resistance of the human body, wrist straps and shoes. The instrument can detect and alarm when the comprehensive resistance of the human body is greater than 109Ω and less than 105Ω. The SL-031 double-legged human body comprehensive tester is equipped with 750KΩ-10MΩ circuit (for testing wrist band) and 750KΩ-100MΩ circuit (for testing). Shoes), this instrument is ideal for testing wrist straps and shoe covers.

one. Characteristics
1. This product features outstanding ability to quickly test ESD equipment, and three independent devices (left shoe, right shoe, wrist band) complete ESD testing at one time. see picture 1
2. Three different status displays, LO (below the set value), PASS (within the set value range), HI (higher than the high value) have an alarm function. Specific parameters are shown in Table 1.
3. If other power adapters are used, the under-voltage 9V under-power indicator will illuminate, which will affect the test accuracy. The power adapter is AC or DC12V and cannot be greater than 15V! The extended communication interface is a dedicated program for downloading programs, and users should not use it. Do not insert with metal objects