ESD Table Mat Anti-static Grounding Wire Description

Oct 08, 2018 Leave a message

ESD table mat anti-static grounding wire description


When the anti-static mat is grounded, it needs to be connected to the anti-static grounding wire. However, some enterprises do not have real anti-static grounding for cost considerations, but connect the equipment grounding wire to a certain three-phase circuit. Go to the ground! It is recommended that everyone grounding must be of good quality. It is connected to the anti-static special ground. Why do you say this? Because different grounding wires have different functions, if you think about anti-static, you must use anti-static grounding wires, because they have ground wires, lightning protection ground wires, lighting ground wires, etc. The balance point, which is different from our actual anti-static, will form a voltage drift, or zero drift, in fact, there is no real grounding, so the anti-static mat must be connected to the anti-static grounding Go online, in order to ensure that the quality of anti-static products will not be problematic, and the static electricity will be well discharged.

Anti-static grounding wire for the mat: It is equipped with claw-type metal clasp for easy installation on the mat. The other end of the grounding cable is equipped with a banana plug and an alligator clip for easy insertion into the grounding socket and directly clamping the grounding wire.

Anti-static mat grounding standard method:

A. Put the anti-static mat on the workbench and install the anti-static grounding wire on the corner of the workbench. After the test passes, the anti-static grounding device is basically completed.

B. Draw a small opening into the anti-static table mat, insert it into the star claw part of the grounding wire, and the star claws must be tightly fastened with the anti-static table mat;

C. The other end of the anti-static grounding wire is an all-in-one anti-static grounding busbar for the alligator clip;

D. Measure whether the anti-static grounding wire, anti-static mat and the ground are connected.