Precautions During Use Of Ionizing Ion Fan Device

Jan 06, 2020 Leave a message

Precautions during use of ionizing ion fan device


Static elimination devices (such as ion fans) can be divided into AC and DC according to the high voltage used by their discharge electrodes (discharge needles). There are high-frequency and ordinary AC (commercial frequency) in AC, and DC in Divided into continuous DC type, DC pulse type.


The difference between AC and DC static elimination devices is that a discharge needle of an AC static eliminator can alternately generate positive and negative air ions. The discharge electrode consists of a discharge needle and a ground electrode. A ground electrode is required. The discharge electrode consists of positive and negative independent discharge pins. Where there is no external air supply (such as fans, compressed gas, etc.), the DC type static eliminator is farther away than the AC type static eliminator. In the case of external air supply, the static elimination distance mainly depends on the Structure, air volume and strength of high voltage power supply.


The difference between the AC and DC static elimination devices requires special attention to the difference in ion balance. The AC type static eliminator generates both positive ions and negative ions on the same discharge needle. There will be no major changes, and the ion balance performance is better. DC type static eliminators because the discharge needle is composed of separate positive and negative electrodes, the ion balance is poor when used at close range. In addition, the discharge needle is affected by the environment and the needle pollution degree will affect the ion balance, especially the discharge. After the needle is used for a long time, the positive and negative discharge needles wear differently, and the ion balance cannot be corrected after cleaning.


The discharge needle will be contaminated after long-term use, which directly affects the static elimination performance and ion balance. Therefore, the static elimination electrode section should be cleaned regularly during use, especially the DC type static eliminator discharge needle is more susceptible to pollution than the AC type Appliance cleaning should be more frequent, and the degree of wear of the positive and negative discharge needles is different. Periodic ion balance testing is required, and the discharge needles should be replaced in time when the discharge needles are severely worn.