Ionizing bars can be used at the slitting station of a lithium-ion battery production line.
Hazards of Static Electricity:
Static electricity generated during the slitting process can cause electrode sheets to drift or wind improperly. It may also attract dust and metallic impurities, leading to the presence of foreign objects within the battery, which can result in self-discharge or even short circuits.
Solution:



The client has opted to use our SL-006C long-range ionizing bars for static elimination. Field measurements indicate that, following treatment, the residual voltage in most areas is kept below 1000V, while the residual voltage at the intersection point of two ionizing bars is approximately 1200V. These levels are acceptable to the client, and the project is currently undergoing long-term stability testing.