The new product is here, smt automatic parts counter
Product Principle


The chip counter adopts the photoelectric sensor principle, uses the corresponding relationship between the part carrier tape guide hole and the part, through a dedicated processing chip and large-scale centralized circuit processing, to achieve zero error, accurately measure the number of SMD parts, and realize convenient and fast counting. It is an efficient auxiliary equipment for SMT material management.
feature of product
Product features
Calculate the number of parts in a fully automatic way, which is convenient for feeding materials, and the operation of the material distribution operation is simple. The unique design of preventing the material belt from falling off reduces the damage to the material belt to a minimum. It can be counted in the positive direction. The number can be preset, and the number can be accurately calculated. error. A scanner and bar code printer can be installed to facilitate management operations.
Product specifications
Product specifications
Power supply: AC220V/A100V, 50/60 HZ, single motor 25W, the machine has 2 motors total 50W
Counting range: -99999--99999PCS
Dimensions: L470*W300*H180mm
Weight: 10KG
Counting speed: 13 seconds per plate/5000
Support for detecting missing parts
Support tailings automatic stop
Applications
Product application
SMD belt-type parts are applicable to belt wheel diameter: any size is applicable
Tape interval (PITCH): 1, 2, 4, 8, 10, 12, 16, 24, 32, 44, 56mm Tape width (WIDTH): 4, 6, 8, 12, 16, 24, 32, 44 , 56mm
Operating procedures
Connect the power cord to the host and connect to the AC220V/A100V power supply
Turn on the POWER switch on the machine panel, and the LCD panel will light up at this time
Press PITCH, set the spacing of the parts to be counted and press "ENTER" to confirm. Place the parts to be counted on the tray on the left.
Manually pull out the material belt and clamp it between the stopper and the counting gear, and align the middle hole of the first part and the space with the middle line of the stopper.
Press the "Stop/Clear" button for 2 seconds to reset the number to zero. Note: The counting gear will rotate to count when the material belt is pulled. Press this to reset the number to zero.
Press the "set button" to switch between manual and automatic modes. When selecting the automatic mode, you must enter the number you want to count, otherwise the motor will not rotate when you press the "forward rotation" button.
Pull the material belt by hand to wind it on the empty material tray, press "forward rotation/RIGHT" to count.
When the quantity is reached, the motor will stop. Due to the principle of inertia, the number of counts may be more or less than the set value by about one. You can manually rotate the tray until the LCD displays the set value, that is, the number of parts.
After the count is completed, press "Reverse/LEFT" and the tape will be rewinded to the original left tray, and the rotation will stop.