The New Product Is Here, Smt Automatic Parts Counter

Jul 08, 2021 Leave a message

The new product is here, smt automatic parts counter


Product Principle

The chip counter adopts the photoelectric sensor principle, uses the corresponding relationship between the part carrier tape guide hole and the part, through a dedicated processing chip and large-scale centralized circuit processing, to achieve zero error, accurately measure the number of SMD parts, and realize convenient and fast counting. It is an efficient auxiliary equipment for SMT material management.


feature of product

Product features


Calculate the number of parts in a fully automatic way, which is convenient for feeding materials, and the operation of the material distribution operation is simple. The unique design of preventing the material belt from falling off reduces the damage to the material belt to a minimum. It can be counted in the positive direction. The number can be preset, and the number can be accurately calculated. error. A scanner and bar code printer can be installed to facilitate management operations.


Product specifications

Product specifications


Power supply: AC220V/A100V, 50/60 HZ, single motor 25W, the machine has 2 motors total 50W


Counting range: -99999--99999PCS


Dimensions: L470*W300*H180mm


Weight: 10KG


Counting speed: 13 seconds per plate/5000


Support for detecting missing parts


Support tailings automatic stop


Applications

Product application


SMD belt-type parts are applicable to belt wheel diameter: any size is applicable


Tape interval (PITCH): 1, 2, 4, 8, 10, 12, 16, 24, 32, 44, 56mm Tape width (WIDTH): 4, 6, 8, 12, 16, 24, 32, 44 , 56mm


Operating procedures


Connect the power cord to the host and connect to the AC220V/A100V power supply

Turn on the POWER switch on the machine panel, and the LCD panel will light up at this time

Press PITCH, set the spacing of the parts to be counted and press "ENTER" to confirm. Place the parts to be counted on the tray on the left.

Manually pull out the material belt and clamp it between the stopper and the counting gear, and align the middle hole of the first part and the space with the middle line of the stopper.

Press the "Stop/Clear" button for 2 seconds to reset the number to zero. Note: The counting gear will rotate to count when the material belt is pulled. Press this to reset the number to zero.

Press the "set button" to switch between manual and automatic modes. When selecting the automatic mode, you must enter the number you want to count, otherwise the motor will not rotate when you press the "forward rotation" button.

Pull the material belt by hand to wind it on the empty material tray, press "forward rotation/RIGHT" to count.

When the quantity is reached, the motor will stop. Due to the principle of inertia, the number of counts may be more or less than the set value by about one. You can manually rotate the tray until the LCD displays the set value, that is, the number of parts.

After the count is completed, press "Reverse/LEFT" and the tape will be rewinded to the original left tray, and the rotation will stop.