First, the purpose

All operations on electrostatic sensitive devices, parts, components and equipment that are not packaged with electrostatic protection or electrostatic protection must be carried out in the electrostatic protection area


Second, the scope of the electrostatic protection area


For the operation of all electrostatic sensitive devices, parts, components and equipment that are not packaged or packaged with electrostatic protection


Including: manufacturing, processing, assembly, assembly, installation, packaging, labeling, maintenance, testing, inspection, transshipment and other operations or processes


Third, the establishment of electrostatic protection area


The electrostatic protection area can be an entire plant, an entire room, a workstation or a designated area


The electrostatic protection area should have a clearly identifiable boundary

Fourth, the management and control requirements of the electrostatic protection area


Control of insulators

Control of isolated conductors

Management and control of ESD test items

Five, the control of insulators


All insulators that are not necessary for production, such as coffee cups, food wrappers and personal items, should be moved out of the electrostatic protection area