Ion wind snake operation and use

May 04, 2021 Leave a message

Ion wind snake operation and use

1. Connect the air inlet pipe to the air inlet of the high-frequency ion wind snake.

2. The grounding terminal of the high-frequency ion wind snake is grounded (connected to the machine feet, cold water pipes or special grounding holes, not hot water pipes or other gas pipes), and can also be equipped with a 3-pin plug without additional grounding. .

3. Turn on the power switch on the high-frequency ion wind snake, the device is in the waiting state, when the photoinductor

When the responder senses a worker, the built-in air valve opens, and the power is turned on, and the equipment starts to work. At this time, the power indicator and ion indicator are on, indicating normal.

4. The high frequency ion wind snake outputs a high voltage of 5.6KV, but the current is only 80uA,

There will be a weak sense of electric shock when touching the ion needle. To ensure safety and protect the ion needle,

Please do not touch the ion needle. After long time use, wipe the ion needle with alcohol to keep

clean. The ion needle is damaged or the working life is reached, and the corona discharge cannot be generated normally.

The sub-indicator will not light up, and the ion needle needs to be replaced.

5. The object that needs to remove static electricity is within 3~10cm of the tuyere. The effect of removing static electricity is the best, but don’t

The distance is too close (above 30mm).

6. If the photoelectric sensor is too sensitive, you can use the plastic screwdriver to rotate the sensor

The screw hole is adjusted clockwise, if it is not sensitive enough, adjust it counterclockwise.