What are the anti-static measures of the electronics factory

Oct 10, 2018 Leave a message

What are the anti-static measures of the electronics factory?



 As the name suggests, the electronics factory is a place for the production of electronic products. In order to avoid the interference and influence of static electricity on the quality of electronic products, the electronics factory must take anti-static measures. First, it must grasp the electrostatic sensitivity of the electronic products themselves. After planning the relevant electrostatic protection scheme, after mastering the electrostatic sensitivity, the electrostatic protection is started from the two parts of the electrostatic protection measures and the system. Next, Xingye Zhuohui anti-static overalls manufacturers and everyone to introduce the anti-static measures of the plant.


First, the electrostatic safety workbench


    1. The electrostatic safety workbench is a basic component of the anti-static work area. It consists of a workbench, an anti-static table mat, a wristband connector and a grounding wire.


    2. There should be no less than two wristband connectors on the anti-static table mat, one for the operator and the other for the technician, the inspector or other personnel.

    3. If necessary, the electrostatic safety workbench should be equipped with an ion wind static eliminator.


    4. It is not allowed to stack plastic boxes (sheets), rubber, cardboard, glass and other debris that are easy to generate static electricity on the static safety workbench. The drawings and materials should be placed in the anti-static paper bag.


2. Anti-static wrist straps should be worn with anti-static wrist straps. The wrist straps should have good contact with human skin. The wrist straps must be non-irritating and non-allergic to the human body. It should be in the range of 106 to 108 Ω.


Third, anti-static containers In the development and production of electronic equipment, all storage, turnover SSD containers (component bags, transfer boxes, printed board racks, component storage boxes, etc.) should have electrostatic protection. Metal and ordinary plastic containers are not allowed. If necessary, the tote box for the storage unit should be grounded.


Fourth, the ion wind static eliminator to eliminate the static charge on the surface of the insulating material should use an ion wind static eliminator.


Five, anti-static overalls


    1. Persons entering the anti-static work area or contacting the SSD should wear anti-static overalls. The anti-static overalls fabrics should meet the requirements of GB 12014.

    

    2. In an environment with a relative humidity greater than 50%, the anti-static overalls are allowed to use pure cotton products.


Sixth, anti-static work shoes into the anti-static work area or contact SSD personnel should wear anti-static work shoes, anti-static work shoes should comply with the relevant provisions of GB 4385. Normal shoes are generally allowed, but a conductive shoe bundle or heel strap should be used at the same time.

7. When the anti-static transport vehicle transports SSD or the whole and parts containing SSD, the transport vehicle with anti-static performance should be used.