What to pay attention to when grounding installation
The anti-static grounding sub-system can use the fault protection ground wire or the signal reference ground wire (DC working ground wire) as the grounding bus.




Do not allow the wiring of the AC line to be placed close to or parallel to the DC ground wire to prevent interference to the DC signal.
The connecting wires of the grounding sub-systems should be isolated from each other. For this reason, wires with an insulating sheath should be used.
The connection between the grounding trunks should be brazed, welded, or pressure connectors, clamps, etc. for lap connection.
The grounding terminals of anti-static tools, devices, etc. allow the use of various clip-on connectors that are easy to assemble and disassemble, such as alligator clips, plug sockets, etc., but reliable electrical connections should be ensured.
The fault protection ground wires of anti-static workbenches, devices, equipment, etc. should use multi-stranded plastic-coated wires with a minimum cross-sectional area of not less than 1.25 square millimeters, and the color of the outer skin should be yellow-green.