How many grounding points are needed for anti-static floor mats




Before the anti-static floor mat is laid, it is necessary to lay the grounding copper mesh first, and the connection between the grounding copper mesh and the grounding wire needs to use a professional copper wire braided mesh belt, so whether an anti-static floor mat only needs a copper mesh belt Well, the answer is obviously no. First of all, no matter the size, as long as it is a room or a single area, two grounding copper grids need to be connected to the grounding wire. Then, if a laying area is larger than 140m2, then for every 30m2 increase, a copper mesh belt needs to be added, and it needs to be evenly distributed when connected to the ground wire, that is, the distance between each copper mesh belt should be the same as possible.
When we accept customer orders, we will inquire about the specific laying conditions of customers in detail, help customers calculate the corresponding number of copper mesh belts, equip them with the required auxiliary materials, and minimize unnecessary troubles for customers.